Our Offered Machines to you

Who are in extremely love with eco friendly system..

HGT Hydraulic Gyratory Crusher

HGT Hydraulic Gyratory Crusher

HGT Gyratory Crusher is a new-type intelligent coarse crusher with big capacity and high efficiency. It integrates mechanical, hydraulic, electric, automated, and intelligent controlling technologies which grant it with advantages traditional crushing

European Type Jaw Crusher PEW

European Type Jaw Crusher PEW

Jaw crushers has stationary jaw crusher, portable jaw crusher and mobile jaw crusher (crawler jaw crusher). Jaw crusher (PEW Series) is not only able to be used together with mine-selecting and gravel processing equipments but also be used independen

Jaw Crusher PE

Jaw Crusher PE

Jaw crusher is driven by a motor, and the moving jaw moves up and down via eccentric shaft. The angle between fixed jaw and moving jaw becomes smaller when the moving jaw runs down, then the materials are crushed into pieces. It will become bigger whe

HPT Hydraulic Cone Crusher

HPT Hydraulic Cone Crusher

Base on the latest technology and decades of years’ producing experience, Our Company designed the HPT series cone crusher. It has excellent crushing efficiency and good hydraulic control system. Now the HPC series cone crusher has wide application

HST Hydraulic Cone Crusher

HST Hydraulic Cone Crusher

HST Single Cylinder Hydraulic Cone Crusher is a new high-efficiency cone crusher independently researched, developed and designed by SBM through summarizing over twenty years of experience and widely absorbing advanced American and German technologies

CI5X Series Impact Crusher

CI5X Series Impact Crusher

CI5X Impact Crusher breaks materials with impact force. When materials enter the working area of hammer, they may be crushed under the high-speed shock and then thrown onto the impact device above the rotor for another crushing. Next, materials bounce

VSI6X Series Vertical Crusher

VSI6X Series Vertical Crusher

Due to the increasing market demand for the scale, intensification, energy conservation, environment protection and high-quality machine-made sand, SBM, a Chinese professional sand maker manufacturer, further optimizes the structure and function of tr

VSI5X Vertical Shaft Impact Crusher

VSI5X Vertical Shaft Impact Crusher

VSI Crushers Working Principle Raw material falls down into feed hopper, and then enters rotor through central entrance hole. It is accelerated in high-speed rotor, and then is thrown out at speed of 60-75m/s. When hitting anvil, it is crushed. Final

VSI Vertical Shaft Impact Crusher

VSI Vertical Shaft Impact Crusher

VSI Series vertical shaft impact crusher is designed by reputed German expert of SBM and every index is in worlds leading standard. It incorporates three crushing types and it can be operated 720 hours continuously. Nowadays, VSI crusher has replaced

VUS aggregate optimization system

VUS aggregate optimization system

The VU system is a global most-advanced dry-process sand-making system. The system is constructed like a tower. Its fully-enclosed layout features high integration. It integrates the functions of high-efficiency sand making, particle shape optimizatio

MTW-Z European Trapezium Mill

MTW-Z European Trapezium Mill

MTW European Grinding Mill is innovatively designed through deep research on grinding mills and development experience. It absorbs the latest European powder grinding technology and concept, and combines the suggestions of 9158 customers on grinding m

5X Series Roller Grinding Mill

5X Series Roller Grinding Mill

Grinding roller of MB5X Pendulum Roller Grinding Mill l adopts diluted oil lubrication. It is a technology initiated domestically which is maintenance-free and easy to operate. Diluted oil lubrication is oil bath lubrication, more convenient than grea

MTW Trapezium Mill

MTW Trapezium Mill

MTW European Grinding Mill is innovatively designed through deep research on grinding mills and development experience. It absorbs the latest European powder grinding technology and concept, and combines the suggestions of 9158 customers on grinding m

LM Vertical Mill

LM Vertical Mill

LM Vertical Grinding Mill integrates crushing, drying, grinding, separating and transport. The structure is simple while the layout is compact. Its occupational area is about 50% of that of the ball-milling system. The LM grinding mill can also be arr

TGM Trapezium Mill

TGM Trapezium Mill

TGM Super Pressure Trapezium Mill The operation principle of main unit of Trapezium mill is that main unit runs with the central shaft that is driven by a gear box. The top of the shaft is connected with a quincunx stand on which a grinding roller is

vibration in raw mill fan

Raw Mill Bag House Fan Vibration Critical Issue AMP

Hi there, I would like to share the vibration trend of our Raw mill Bag House Fan. the fan has been running with abnormal vibration from 4.5 to 7 mm/sec on Horizontal point NDE bearing HH for last 6 months. the main problem is coating and fine dust that is coming from the bag house chambers due to worn and useless bags. this coating build up on fan impeller rapidly and results the fan is

More

Vibration In Raw Mill Fan

RAW MILL FAN High Vibration at INBOARD Topic MaintenanceForums. We have only abnormal vibration at RAW MILL FAN INBOARD bearing. What can be the problem? Spectrum has 1X harmonics upto 5X. Read more. Cement Process Fans: Operation and Maintenance Considerations. 13 Mar 2007 Erosion of the fan which hinders the proper functioning of the plant is Also featured are

More

thermography Vibration Condition Monitoring, Fan

Raw Feed Circuit A13 Rotary Valve Motor The motor has increased vibration, mainly in the vertical direction, due to structural looseness. See Fig 1. Gearbox The gearbox input shaft is showing increases due to Fig.2 both input shaft speed vibration and looseness/movement vibration. See Fig 2.

More

Case Studies Machine Monitoring, Vibration Analysis, IoT

Smart vibration monitoring installed on a critical raw mill fan helped in preventing 50 hours and 44 Thousand USD. Read More. Cement/Fan. IDE installed on a critical kiln fan prevented downtime of 144 hours and saved 6.4 Million USD. Read More. Cement/Gearbox. vEdge on a raw mill gearbox helped in preventing unplanned downtime of 50 hours and saved 223 Thousand USD. Read More.

More

Learn About Vibration, Volume 1: Basic Understanding of

11/10/2019· Vibration switches and transmitters are (4-20ma) low cost and gives you 24/7 protection, measuring, trending, alarm, trip settings, time delays and can operate via WIFI or installation of vibration transmitters from critical machines to control room panel meters up to 1000 ft away. Computer can be programmed to alarm if maximum pre-set limits are exceeded to alert you right away. Another

More

Rawmill Wikipedia

Unlike ball mills, feed to the mill must be regular and uninterrupted; otherwise damaging resonant vibration sets in. Hammer mills. Hammer mills (or "crusher driers") swept with hot kiln exhaust gases have limited application where a soft, wet raw material is being ground. The simple design means that it can be operated at a higher temperature

More

Protective Maintenance Fans Cement SlideShare

13/11/2008· Strategies for Vibration Monitoring, protective maintenance and other industrial fan related instruction.

More

Predictive Maintenance, Vibration Sensor For Cement

Infinite Uptime's Vibration Monitoring Solution for Predictive Maintenance has measured high on our expectations of quality, flexibility and in-depth knowledge and has continuously raised the bar. I must say the Diagnostic Services offered at a reasonable cost has increased the reliability of the equipment and reduced the investment in spares-inventory.

More

FOR VERTICAL ROLLER MILLS Loesche

for raw meal, clinker and coal grinding due to their lower capital cost and energy consumption compared to ball mills. Loesche GmbH, Germany, has been a leading supplier of roller mills for over 100 years and in more recent times, has expanded by adding a subsidiary automation company for both hardware and software delivery and project management. The latest addition to the automation software

More

Plant Engineering Understanding fan vibration and

01/05/2001· The Air Movement and Control Association Intl., Inc.’s (AMCA) Standard 204, Balance Quality and Vibration Levels for Fans,” recognizes five different fan application categories (BV-1, BV-2, BV-3, BV-4, and BV-5) for the required balancing grade during manufacturing of the fan (see table). These balance categories are ordered from a less sensitive group (HVAC) to the most sensitive fans

More

VIBRATION ANALYSIS CASE HISTORY Vibrant Technology

Machine Class: Pulp Mill Boiler Recovery Fan Rotating Speed: 4,430 RPM Overall Alarm: 0.400 ips PROBLEM STATEMENT: This machine was experiencing Elevated Vibration response at 11xx RPM following an over‐speed test of the turbine. The dominant response was an out‐of‐phase motion in the

More

Vibration Analysis Explained Reliable Plant

Vibration analysis revealed that once fan No. 2 was turned on, a slight increase in vibration amplitude across all three points of measurement occurred, while fan No. 1 remained the same. Testing showed the highest amplitude appeared in the motor outboard vertical at 0.456 inches per second, with a dominant peak at 841 cycles per minute, according to IVC Technologies. This indicated the

More

The vibration control of raw material vertical roller mill

The vibration control of raw material vertical roller mill system News Date:2015-09-14 14:13:26. The vibration of mill body of vertical roller mill is a normal phenomenon exists in working condition, reasonable vibration is allowed, if the mill has a violent vibration, it will cause damage to millstone, roller lining and accessory equipment. . Therefore, vibration values in working condition

More

Vibration Monitoring: A Case Study Maintenance and

01/01/2014· Coal mill main drive assembly, bag house fans and booster fans As shown in Tables 1-4, the fault-prone components on these units are the gears, bearings, couplings, shafts, impeller/blades and electric motor. Figures 3 and 4 respectively show the schematic and pictorial representations (with the positions of the various VCM sensors) of the coal mill main drive assembly, bag house fan and

More

Case Study Solving a Forced Draft Fan Problem

Mechanical Solutions, Inc. (MSI) was contracted by a paper mill to solve excessive vibration problems on Induced-Draft and Forced-Draft fans and their respective drive trains. This case history discusses the motor driven FD fan problem and solution.. Figure 1. Freeze frame picture from an ODS animation showing the “Rocking” Motion of the FD fan housing.

More

Learn About Vibration, Volume 1: Basic Understanding of

11/10/2019· Vibration switches and transmitters are (4-20ma) low cost and gives you 24/7 protection, measuring, trending, alarm, trip settings, time delays and can operate via WIFI or installation of vibration transmitters from critical machines to control room panel meters up to 1000 ft away. Computer can be programmed to alarm if maximum pre-set limits are exceeded to alert you right away. Another

More

Anti-vibration & machinery mounting guide

The basic principle of vibration isolation is that the machine is entirely isolated/separated from the floor by a resilient material that is ‘tuned’ in such a way that the main disturbing frequencies of vibration are not transmitted through it (or are greatly reduced). The resilient isolation layer may be in the form of a continuous mat, strips or discrete pads depending on the machine

More

Rawmill Wikipedia

Unlike ball mills, feed to the mill must be regular and uninterrupted; otherwise damaging resonant vibration sets in. Hammer mills. Hammer mills (or "crusher driers") swept with hot kiln exhaust gases have limited application where a soft, wet raw material is being ground. The simple design means that it can be operated at a higher temperature

More

Sleeve Bearings General Vibration School

Measuring vibration on the housing of a sleeve bearing is unreliable since the housing moves only a small fraction (perhaps 10% or even less) of what the shaft is moving. Vibration is due to mechanical forces being generated by the machine's rotation. In the absence of such forces (slow rotational speeds combined with excellent alignment and balance, for example), extensive wear can take place

More